Smart double flange level meter pressure transmitter
GLP-3351LDP double flange liquid level transmitter adopts the principle of differential capacitance detection. When the pressure on both sides is inconsistent, the diaphragm in the chamber is displaced. The displacement is proportional to the pressure difference. The capacitor is processed by the circuit. The two-wire current signal whose conversion amount is converted into 4 to 20 mA is sent to the secondary meter to display the liquid level value, and the liquid level value can also be displayed on the meter head. The level transmitter features robust, vibration-resistant, range, zero and damped field continuously adjustable.
Features
*Strong media compatibility.
*High reliability, high precision, high strength.
*Range migration 5:1; high static pressure 14MPa and 31Mpa.
*Range, zero point, full scale, linear externally adjustable.
*Multiple signal output forms, voltage, current, frequency signals, etc.
Main technical parameters
Measuring medium: water, oil and other liquids; air, steam and other gases; high viscosity, easy to crystallize and solid suspended particles are compatible
Reference accuracy: ±0.075% calibration range
Stability: 6 months, ±0.1% URL
Vibration effect: vibration influence at 200 Hz is ±0.05% URL/g in any axial direction
Load impact: no load impact unless the supply voltage changes
Range: 0~30m
Output: 4~20mA
Application
Liquid level/pressure detection of liquids, gases and vapors.