Ultrasonic open channel flow meters designed for sewage treatment applications provide accurate, non-contact flow measurement of wastewater in channels and pipes. These meters are resistant to fouling and debris, ensuring stable performance over time. Bulk purchasers benefit from easy installation, low maintenance, and compatibility with standard output signals like 4-20mA and Modbus.
Measure sewage flow reliably — even in dirty, variable open channels. Gallop’s ultrasonic open channel flow meter is engineered for municipal wastewater plants, pump stations, stormwater monitoring and industrial effluent channels. Designed to reduce site visits, simplify integration with SCADA and lower total cost of ownership while delivering accurate flow data for compliance and process control.
Designed for harsh sewage conditions. Non-contact ultrasonic sensing avoids clogging and wear common with submerged or wetted sensors.
High accuracy across low flows and fluctuating depths. Stable readings in slow, turbulent, or partially filled channels.
Easy integration with existing control systems. Native outputs: 4–20mA, RS485/Modbus, optional HART; Modbus register maps and wiring diagrams included.
Low maintenance & long service intervals. Removable transducer covers, self-cleaning coatings and remote diagnostics reduce O&M time.
Compliance & traceability for reporting. Calibration certificates and optional on-site commissioning available.
Problem: Sensors foul / require constant cleaning.
Solution: Gallop’s non-contact transducer and optional anti-fouling shield minimize buildup. Cleaning cycles extended, fewer site visits.
Problem: Poor accuracy at low flow / irregular channels.
Solution: Advanced signal processing and automatic profile compensation maintain ±1–2% of reading (application dependent) across wide depth ranges.
Problem: Hard to integrate into SCADA / PLC.
Solution: Out-of-the-box 4–20mA and Modbus RS485 support, Modbus register map, and cable termination diagrams make commissioning fast.
Problem: Long procurement cycles and unclear lead times.
Solution: Standard configurable units available from stock; Gallop provides clear lead times, MOQ info and fast quotation for projects.
Municipal sewage treatment plant inflow/outflow monitoring
Combined Sewer Overflow (CSO) and stormwater monitoring
Sewage pump station flow monitoring
Industrial effluent & wastewater discharge compliance
Agricultural/irrigation drainage monitoring where open channels are used
Use these specs on product pages and datasheets. Final specs will depend on model and site conditions — Gallop provides tailored quotes after site review.
| Item | Typical Value / Options |
|---|---|
| Measurement method | Non-contact ultrasonic time-of-flight |
| Channel types | Flume (Parshall, Palmer-Bowlus), weir, natural channel (calibrated) |
| Measured range | 0.01 m³/h — site dependent (customizable) |
| Accuracy | ±1%–±3% of reading (application and flow profile dependent) |
| Outputs | 4–20mA (isolated), RS485 Modbus RTU, optional HART / Ethernet Modbus TCP |
| Pulse / Relays | Optional flow totaliser pulse / alarm relays |
| Power | 9–36 VDC (standard), 85–265 VAC optional |
| Enclosure | IP66 / NEMA 4X (electronics); optional heated enclosures available |
| Transducer material | PVDF / PEEK; optional anti-fouling coating |
| Operating temp | −20 °C to +60 °C (site dependent) |
| Data logging | Onboard SD (optional) or external SCADA logging |
| Certification | Calibration certificate; optional factory test report and local approvals |
| Mounting | Bridge/rail, standpipe, mounting bracket for flume/weir |
| Communications | Modbus register map & wiring diagram included |
Site survey: Gallop recommends a short site survey (photos + simple measurements) to confirm channel geometry and optimum sensor placement. For large projects we offer remote assessment or on-site engineering.
Mounting options: Bracket mount for flumes/weirs, side-wall mount for natural channels, and pole/bridge mounts for stormwater channels.
Wiring & integration: Supplied with wiring diagram for 4–20mA, RS485/Modbus and pulse outputs. We provide Modbus register map and sample PLC code snippets on request.
Calibration & acceptance test: Factory pre-calibrated; on-site calibration and acceptance tests available as an add-on. Calibration certificates supplied.
Typical lead time: Standard models: 2–4 weeks; customized or certified units: depending on scope — Gallop will confirm in quote.
Remote diagnostics: Real-time status via Modbus; error codes and signal quality indicators help reduce unnecessary site visits.
Service intervals: Typical visual inspection every 6–12 months; cleaning only if heavy fouling is present.
Spare parts & upgrades: Transducer assemblies, mounting brackets and cables available worldwide. Firmware updates via service port.
Warranty & service plans: 12–24 month warranty options; extended maintenance & commissioning plans available.
Q: Will this work in a Parshall flume with high solids content?
A: Yes. Non-contact ultrasonic measurement is tolerant of solids in the flow. For heavy solids/floating debris we recommend anti-fouling shields and periodic inspections — Gallop can advise the optimal transducer and mounting.
Q: Which outputs are supported for SCADA integration?
A: Standard: isolated 4–20mA and RS485 Modbus RTU. Optional: HART, Modbus TCP (Ethernet), and pulse outputs. Full Modbus register map provided.
Q: What accuracy can we expect for sewage applications?
A: Typical field accuracy is ±1%–±3% of measured value depending on channel geometry and flow conditions. Gallop provides site assessment to estimate expected performance before purchase.
Q: How often does the sensor need cleaning?
A: Many installations run months between cleanings. Frequency depends on solids and biological growth. Gallop units include self-diagnostics to flag when cleaning is beneficial.
Q: Do you provide calibration certificates?
A: Yes — factory calibration certificates are standard; on-site calibration and third-party verification are available for projects that require them.
Q: Lead time and MOQ?
A: Standard configurable units commonly ship in 2–4 weeks. MOQ: typically 1 unit; bulk/project quotes available with prioritized lead times. Exact timing provided in formal quotation.
Q: Can you supply drawings for procurement and installation?
A: Yes — datasheets, dimensional drawings, mounting details and wiring diagrams are included with every quote.
Bulk buyers focus on meter reliability, measurement accuracy, and environmental protection ratings. Suppliers offering calibration, technical support, and flexible delivery improve procurement outcomes. Volume discounts and supply chain stability are key factors in large-scale sewage treatment projects.
Contact Us
Related Keywords
High Precision Open Channel Flow Meter For Water Management4-20ma Flow MeterDn50 Electromagnetic MeterPulse Output Flow MeterModbus Level SensorHygienic Flow MeterRadar Flow Meter For Water Treatment PlantMulti-Protocol Radar SensorOpen Channel Radar Flow MeterAtex Flow MeterDn100 Vortex Flow MeterLow Temperature Ultrasonic SensorSealed Ultrasonic Level MeterThreaded Paddle Wheel MeterWater Flow TransmitterStainless Steel Radar MeterUltrasonic Sensor For TankHigh Pressure Radar Level SensorAnalog Output Flow MeterIndustrial Radar Flow Meter For Bulk Liquid Measurement2-Wire Ultrasonic SensorIp68 Level TransmitterRs485 Flow Transmitter±1% Ultrasonic Flow MeterNon-Contact Radar SensorFlange Electromagnetic Flow MeterSteam Vortex Flow Meter±0.5% Accuracy Flow MeterBest Radar Flow Meter For Corrosive FluidsRadar Level Transmitter For Silo24v Radar Level TransmitterTurbine Flow Meter For OilUltrasonic Open Channel Meter For Industrial EffluentDigital Level TransmitterUltrasonic Open Channel Flow Meter For Sewage TreatmentChemical Tank Level SensorDn15 Ultrasonic Flow MeterWall Mounted Radar SensorRemote Ultrasonic TransmitterOpen Channel Flow MeterUltrasonic Level Transmitter 4-20maRadar Flow Meter Manufacturer For Oem IntegrationPfa Coating Level SensorDn150 Flow SensorWastewater Ultrasonic Meter