The GALLOP GLP-7 ultrasonic liquid level meter is designed for non-contact, continuous liquid level measurement in water tanks, wastewater treatment systems, storage vessels, pumping stations, and other industrial applications.
With measuring range options up to 20 meters, compact and split-type configurations, local LCD indication, and industrial signal output options, the GLP-7 provides a practical solution for liquid level monitoring and process automation.
The meter uses ultrasonic technology to measure the distance between the sensor and the liquid surface, eliminating the need for direct contact with the measured liquid.
GALLOP also offers OEM/ODM support and application-based product selection for industrial customers.
Model: GLP-7
MOQ: 1PCS
Payment: Bank transfer/ Wire transfer
Lead Time: 5-7 days
OEM/ODM: Available
The GLP-7 measures liquid level using ultrasonic waves without immersing the sensing element in the liquid.
This reduces direct exposure to the process medium and can simplify maintenance in suitable water and wastewater applications.
The non-contact design is especially useful where a conventional immersed sensor may be difficult to maintain.
The GLP-7 product series provides published measuring range options from 0.4 to 20 meters.
The actual measuring distance must be selected according to the installation height, liquid level variation, blind zone, and required measuring span.
The GLP-7 offers configurations including 4–20 mA, RS485, and HART communication options as listed in the GALLOP product specifications.
These interfaces allow compatible configurations to be integrated into industrial monitoring and automation systems.
The required output and power supply combination should be specified when ordering.
Local LCD indication allows operators to read level information at the installation location.
Both compact and split-type configurations are available to accommodate different mounting and operating requirements.
The GLP-7 product specifications list IP68 protection, with a protective housing design intended for demanding industrial and water monitoring environments.
The environmental protection rating and installation requirements of the selected assembly should be matched to the application.
Optional relay output can provide switching functions for suitable pump control or liquid level alarm applications.
The control arrangement should be configured according to the operating requirements of the system.
| Parameter | Description |
| Structure | Split type/ compact type |
| Measuring range | 0.4~20m |
| Output | 2 wire/4-20MA, RS485, HART |
| Voltage | 12V/24V/220V |
| Display | Local LCD Display |
| Pressure | -0.2~1bar |
| Protection Grade | IP68 |
| Accuracy | ±0.5%FS |
| Blind Zone | 0.25-0.5m |
| Ambient Temperature | -15~+50℃ |
| Connection | M66*3 thread |
| Open a hole with | 68mm |
The GLP-7 non-contact ultrasonic level sensor can be used for continuous water level monitoring in storage tanks, treatment facilities, and industrial water supply systems.
Non-contact measurement avoids immersing the sensor in water and allows level monitoring from above the liquid surface.
Ultrasonic liquid level measurement is commonly applied in wastewater systems, including suitable equalization tanks, collection wells, and pumping stations.
The non-contact measurement principle can help reduce direct exposure to contaminated liquids.
However, surface foam, turbulence, and installation obstructions must be evaluated because they can affect ultrasonic echo quality.
The GLP-7 ultrasonic water level meter can provide liquid level information for monitoring water accumulation and changes in pumping station wet wells.
When equipped with appropriate output and control configurations, liquid level measurement can be incorporated into automated pumping and monitoring systems.
Ultrasonic level measurement can be used in compatible storage tanks where a stable acoustic measurement path is available.
For chemical or process applications, evaluate the liquid, vapor conditions, pressure, and temperature before choosing ultrasonic technology.
Non-contact ultrasonic instruments can also support suitable water level monitoring points in reservoirs, channels, and environmental monitoring installations.
The installation must provide adequate measurement clearance and protection from conditions that interfere with the sound signal.

An ultrasonic liquid level meter uses the time-of-flight principle to determine the distance between a sensor and a liquid surface.
The sensor emits an ultrasonic pulse toward the liquid. When the sound wave reaches the surface, part of the signal is reflected back to the sensor.
The transmitter measures the time required for the signal to travel to the liquid surface and return.
The relationship between measuring distance and travel time is:
Distance = Speed of Sound × Travel Time ÷ 2
After determining the distance to the liquid surface, the transmitter calculates the liquid level using the configured tank reference height.
For example, if the reference measurement height is 5 meters and the detected liquid surface is 1 meter below the sensor reference point, the calculated liquid level is 4 meters.
This calculation assumes that the mounting reference and level zero point have been configured correctly.
The instrument can then convert the measured level into a corresponding output signal for monitoring and process control.
Measure the distance between the intended sensor location and the lowest liquid surface to be monitored.
The selected GLP-7 configuration must cover the full required measurement distance while allowing for the instrument's blind zone.
The GLP-7 specifications list a blind zone of 0.25–0.5 meters, depending on the configuration.
The maximum liquid level must remain outside the applicable blind zone for reliable measurement.
Do not select a transmitter based only on the tank height without considering the mounting position.
Ultrasonic level transmitters work best when the reflected acoustic signal can return reliably to the sensor.
Heavy foam, excessive turbulence, filling streams, vapor concentration changes, and internal obstructions may reduce measurement reliability.
For more demanding conditions, a radar level transmitter may be a more appropriate solution.
Check whether your monitoring system requires a 4–20 mA signal, an RS485 interface, or a compatible HART configuration.
The supply voltage, cable arrangement, and communication protocol should be specified together.
Before installation, check the process opening, mounting thread, available clearance, electrical connections, and environmental conditions.
Correct mounting is important for measurement stability and long-term operation.
The following practices help improve measurement reliability:
Install the sensor above the liquid surface. Position it so that the measurement path is directed toward the intended liquid surface.
Avoid internal obstructions. Keep the ultrasonic beam away from ladders, pipes, agitators, and other objects that may produce unwanted echoes.
Consider filling streams. Avoid positioning the sensor where incoming liquid interferes with the acoustic signal.
Maintain adequate blind-zone clearance. Ensure that the maximum liquid level does not enter the instrument's blind zone.
Configure the measurement reference. Set the correct zero point, tank height, and output scaling according to the installation.
Check operating conditions. Confirm that temperature, pressure, humidity, and mounting conditions remain within the selected model's ratings.
Commissioning should include verification of the measured level against a known physical reference.
Both ultrasonic and radar level transmitters can provide non-contact liquid level measurement, but their operating principles differ.
| Comparison | Ultrasonic Level Meter | Radar Level Transmitter |
|---|---|---|
| Technology | Sound waves | Electromagnetic waves |
| Contact with Liquid | No | No |
| Typical Application | Water tanks and suitable industrial liquids | Water, chemicals and more demanding process conditions |
| Effect of Vapor Conditions | Can influence sound propagation | Generally less sensitive to changes in vapor temperature |
| Foam | Can reduce echo reliability | Depends on foam properties and radar configuration |
| Installation | Requires suitable acoustic path and blind-zone clearance | Requires suitable antenna, clearance and echo conditions |
| Selection Priority | Suitable ambient-pressure applications with favorable echo conditions | Applications needing greater tolerance of certain process conditions |
For water tanks and conventional wastewater level monitoring, an ultrasonic liquid level meter may provide a practical solution.
For complex process tanks involving significant vapor effects or challenging measurement conditions, GALLOP can help evaluate its radar level measurement products.
GALLOP has supplied industrial measurement instruments since 2005 and provides technical selection and OEM/ODM services to international customers.
For GLP-7 ultrasonic level measurement projects, we offer:
Application-based instrument selection
Compact and split-type configuration options
Industrial output and power supply options
Local level indication
Support for suitable OEM requirements
Factory inspection and quality control
Technical assistance with installation and operation
Our team can help customers select a suitable configuration according to tank dimensions, measurement range, operating conditions, and monitoring system requirements.
An ultrasonic liquid level meter is a non-contact instrument that uses reflected sound waves to determine the distance to a liquid surface and calculate liquid level.
GALLOP lists measuring range options up to 20 meters for the GLP-7. The suitable configuration depends on the installation and required measurement distance.
Yes, it can be used for suitable wastewater level measurement applications. Heavy foam, turbulent surfaces, vapor conditions, and tank obstructions should be evaluated before installation.
Ultrasonic level measurement is generally more appropriate for ambient-pressure or suitable low-pressure applications. The process pressure, vapor conditions, and device rating must be checked. For demanding pressurized tanks, radar technology may be preferable.
An ultrasonic level meter measures the distance to a surface to determine liquid level. An ultrasonic flow meter measures or calculates fluid flow using an appropriate flow measurement principle. These instruments are designed for different measurement tasks.
Need a non-contact liquid level measurement solution for your project?
Contact GALLOP with your tank height, liquid type, measurement range, operating conditions, power supply, and required output signal.
Our team can help select a suitable GLP-7 configuration, answer technical questions, and provide a quotation for your application.